Window Units in Every Room, No Ducts, Landmarked Facade: Putting Central Air or Ductless Into a Brooklyn Brownstone
Five window units hang off the back of a Stuyvesant Heights brownstone, one in each bedroom and one in the kitchen, and the Con Ed bill in August reads like a second mortgage. The house has steam radiators, 11-foot ceilings, plaster on brick, no attic and no ducts, and a front facade the Landmarks Preservation Commission has opinions about. MJ HVAC Brooklyn, 1290 Fulton St, Brooklyn, NY 11216, (929) 405-1919, puts cooling into houses like that all spring, and an HVAC Contractor Brooklyn brownstone owners hire for it has three routes and a set of rules that decides which one the house gets.
Why Brownstones Are the Hard Case
A detached colonial in Marine Park gets an air handler in the attic and ducts to every ceiling in a day. A brownstone has a cockloft above the top floor a foot deep, party walls shared with the neighbors, floor-through apartments stacked four high, original plaster and moldings the owner paid for, and a rear yard the size of a parking space. The equipment has to go somewhere the house did not plan for, and the ducts, if there are ducts, have to get through 150 years of structure without destroying it.
Ducted From the Top Down
An owner’s duplex on the top two floors can take a conventional system. The air handler sits in the cockloft or a closet on the top floor, supply ducts run in soffits along the hallway ceilings and drop into each room high on the wall, and the condenser goes on the roof. The ceilings are tall enough to lose a foot to a soffit without anyone noticing. The lower floors stay on window units or get their own system. Condensate from a cockloft air handler goes to a drain with a float switch in a secondary pan under it, since the alternative is the parlor ceiling.
High-Velocity for the Floors Nobody Wants to Open
High-velocity systems run 2-inch flexible supply tubing through the wall cavities and between the joists where a conventional duct would never fit. The outlets are small round openings in the ceiling or high on the wall. The air handler is compact and the system moves air fast enough to mix a room without drafts. In a brownstone with intact plaster and moldings it is the way to cool the parlor floor without soffits. It costs more than a conventional system, needs sound attenuator tubing to run quietly, and takes an installer who has done it in a brownstone before, which narrows the field in Brooklyn.
Ductless for Floor-Throughs and Rentals
A multi-zone ductless system puts a wall unit or a ceiling cassette in each room, fed by a condenser in the rear yard or on the roof through a 3-inch hole per head. No ducts, no soffits, the fastest install and the easiest to meter per apartment, which is why landlords with a brownstone cut into three units pick it. The heads heat too, and with a cold-climate condenser and a Con Ed Clean Heat rebate the system carries the apartment most of the winter while the steam boiler handles the coldest nights. The tradeoff is the look of the heads on the wall of a room with original plaster medallions. Ceiling cassettes and slim ducted heads hidden in a closet soffit solve that for owners who care.
Where the Condenser Goes and What Landmarks Allows
Stuyvesant Heights, Bedford, Clinton Hill, Fort Greene, Park Slope, Crown Heights North and Prospect Heights are landmarked districts. The Landmarks Preservation Commission permits anything visible from the street, and a condenser or a line set cover on the front facade is the kind of thing that gets a violation and a removal order. Rear yards and roofs set back from the front parapet are the answer. A roof condenser needs a hoist or a path through the house, a roofer for the penetration, vibration isolators so the top floor tenant does not hear it, and an electrician for the disconnect on the roof. Rear yards that are 15 feet wide put the condenser a few feet from the neighbor’s kitchen window, and a quiet variable-speed unit on a wall bracket keeps the peace.
Co-ops, Condos and Multi-Family Metering
A condo in a converted brownstone or a co-op in a prewar building on Eastern Parkway requires an alteration agreement, the contractor’s insurance, the equipment specs and a drawing before a hole goes through the exterior wall. Buildings with existing through-wall sleeves make it easy. Two-family and three-family houses raise the metering question, which condenser lands on which Con Ed meter, and the lease needs to say who pays for the cooling the landlord just installed.
Sizing, Electrical and Con Ed
A Manual J load calculation sizes the system by room, with the brick walls, the single-pane windows and the exposure counted. Oversized equipment in a brownstone short cycles and leaves the parlor floor clammy. Every condenser needs a dedicated 240-volt circuit sized from its nameplate, a disconnect and a surge protector, and a brownstone on 100-amp service with two multi-zone condensers coming in gets a load calculation and often a 200-amp upgrade with Con Ed in the loop. That number goes next to the HVAC quote before anything is signed.
What Cooling a Brownstone Costs
A multi-zone ductless system for one floor is the entry point. A ducted system for an owner’s duplex with a cockloft air handler and a roof condenser is the middle. A high-velocity system through the parlor and garden floors with the plaster kept intact is the top of the residential range. The electrical upgrade, the roof work, the co-op fees and the landmarks paperwork sit on top of whichever route the house takes. Spring quotes beat July quotes, since July is when every installer in the borough is booked three weeks out.
MJ HVAC Brooklyn at 1290 Fulton St installs central air, high-velocity and ductless systems across Bed-Stuy, Clinton Hill, Fort Greene, Crown Heights, Park Slope and Prospect Heights. (929) 405-1919.
MJ HVAC Brooklyn
1290 Fulton St, Brooklyn, NY 11216
(929) 405-1919
https://mjhvacbrooklyn.com